McGinley Services is one of the leading providers of air conditioning repair and air conditioning service in Media, PA, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.

You'll find we take our job seriously and highly value the trust that is placed in us. McGinley Services goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Media, PA. Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.

Get Your Quote Today

Customers Current Line Set Is Ran Through Window Wants To Move Through Wall We Will Need To Pump Down Refrigerant As Much As Possible, Disconnect Power From Electrical Box Outside, Disconnect Line Sets, Drill Through Wall With Core Bit, Remake Copper And Electrical Connections, Seal Hole In Wall, Braze Linesets Inside And Out, Pressure Test System, Vacuum System, Add About 2 Lbs Of R-22 Refrigerant, Test System To Make Sure It’s Operating Properly
Dylan , B. Media, PA
01-12-2024
5-6 Yr Tune Up On 5 Year Old Ac System Flushed The Drain Line Inside Pulled Door Back Coil Looks Good TXV Unit Air Filter Looks Clean Temp Split Of 16.7 Degrees All Electrical Reading Within Spec Outdoor Unit Is Level Coil Is Clean Leaves And Debris Collect In Unit Moderately All Electrical Within Specs Recommend Membership To Stay On Track With Tune-ups.
Michael , J. Media , PA
02-09-2024
Call For No Ac On 10 Year ICP Ac Unit Discovered Only 5 Psi In System And Failed Capacitor. Spoke With Home Owner And Discussed Options. Refilled R410A Refrigerant To Factory Spec (6#12oz) And Added Dye And Sealant Charge May Or May Not Seal Leak But Dye Atleast Will Allow Visual Detection Of Leak In The Future. Replaced Capacitor And Tested Motors. Compressor 5.8 Amps And Fan 0.70amps Both With In Spec. Ac Running On Departure
Jane , K. Media, PA
09-03-2023