Are you looking for gas furnace maintenance in Media, PA ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Media, PA. McGinley Services has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on McGinley Services to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Media, PA

Get Your Quote Today

Performed Tune Up On 20 Year Old System System Was Working Properly Customers Were Interest In An Estimate For New Systems
George , G. Media , PA
12-21-2023
Crawl Space Unit Blower Motor, Inducer Motor, And Flame Sensor Read Within Range. Blower Wheel And Filter Clean. Board Is Free Of Any Damages. Electrical Connections Tight And Clean. Gas Pressure At 3.5. System Running 14 PPM CO. Humidifier Pad Is Brittle, Recommend Replacement. Basement Unit Blower Motor, Inducer Motor, And Flame Sensor Read Within Range. Blower Wheel And Filter Clean. Board Is Free Of Any Damages. Electrical Connections Tight And Clean. Gas Pressure At 3.5. System Running 9 PPM CO. UV Light Is Operational. Humidifier Pad Is Brittle, Recommend Replacement. 3rd Floor Blower Motor, Inducer Motor, And Flame Sensor Read Within Range. Blower Wheel And Filter Clean. Board Is Free Of Any Damages. Electrical Connections Tight And Clean. Gas Pressure At 3.5. System Running 98 PPM CO. UV Lights Are Out, Recommend Replacement. Humidifier Operational
Robert , T. Media, PA
10-11-2023
Preformed Tune Up On 9 Yo Raheem Furnace. Inducer Motor, Flame Sensor, Gas Pressure, And Blower Capacitor Test Within Range. Blower Wheel Is Clean. Can Not See Data Plate On Blower Motor, Motor Running At 9.9 Amps. Condensate Pump Discharges In A Reasonable Amount Of Time. Electrical Connections Tight And Clean. Replaced Filter. No Recommendations At This Time.
Glenn , B. Media , PA
10-06-2023
2nd Floor Furnace Running Without Issue. Add On Uv Bulbs Are Not Working And Humidifier Solenoid Assembly Leaking When Valve Is On. Crawlspace Unit Has Breached Collector Box (part Of Heat Exchanger), Low Inducer Draw, Flame Sensor Had Signs Of Normal Wear And Tear, Capacitor Running Outside Of Its Limit. No Co Present In House Air. Unit Turned Off At Gas Valve And Electric Switch At Unit Basement Unit Has Breached Heat Exchanger (cracks And Missing Rivots). Due To Age And Parts Being Unavailable Replacement Is Advised. Unit Turned Off At Gas Valve And Electrical Switch At Unit.