Our Service Area> secane,pa

Providing Exceptional Service in Your Community

Water or Steam Boiler Repair

If your heating system in Secane, PA is not working it is likely your boiler needs repair or a good servicing. At times the fix is simple, at times not. Our heating service technicians have years of experience working on hot water or steam boiler systems like yours in Secane, PA. McGinley Services service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our boiler repair, service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on McGinley Services to advise you properly and to do excellent work promptly.

Get Your Quote Today

Upon Arrival Boiler Was Not Firing Up. Went To Boiler And Found That The Zone Thermostats Were Calling At The Zone Board, And Zone Board Was Sending Power To The Zone Valves However The Zone Valves Are Not Opening All The Way To Make The End Switch. I Tried To Manually Open However It Is Stuck The Body Is Bad On Zone 1 And Zone 3. The Zone Valves Need To Be Replaced. Also System Was Low On Water Pressure. There Is No Auto Fill On The Boiler. Only Zone 2 Valve Works Is The Laundry Room. However This Is A Old Mercury Thermostat That Is Not Accurate Temperature Wise. For Now I Am Going To Put The Main Heat Onto That Zone So It Will Heat The House As A Temporary Repair. All Three Zones Heating And Returning Hot. Homeowner Aware This Is Not A Complete Fix.
Jessica , N. Secane, PA
02-02-2024
Boiler Off At Emergency Switch On Boiler Upon Arrival. 0 Psi In Boiler. Advise Replacing Auto Feeder. Boiler Is Using Passive Air Management. 2 Purge Valves Require Screw Driver, 1 Handle Is Deteriorating. Auto Feeder Bypassed With Gate Valve.
Chris, F. Secane, PA
12-18-2023
Boiler Off At Emergency Switch On Boiler Upon Arrival. 0 Psi In Boiler. Advise Replacing Auto Feeder. Boiler Is Using Passive Air Management. 2 Purge Valves Require Screw Driver, 1 Handle Is Deteriorating. Auto Feeder Bypassed With Gate Valve. Turned On Boiler, Increased Water Pressure. Only 2 Areas Coming Back Hot. Pump Operates Within Range. Area Around Boiler Appears Wet. Replaced Relief Valve And Expansion Tank. Purged Air From System. All Areas Getting Hot Upon Departure. Thank You For Your Time And Business -Bobby
Chris, F. Secane, PA
12-14-2023
Found Gas Valve To Be Failing Intermittently. Replaced Gas Valve, Toggled Power Several Hundred Times To Verify That Was The Root Cause. System Did Not Fail With New Gas Valve. System Running Upon Departure. Thank You For Your Time And Business -Bobby
Chris, F. Secane, PA
12-14-2023
Boiler Not On Upon Arrival Thermostat Has Visual Heat Damage Thermostat Is Not Sending 24 Volts To The Unit Unit Is Also Not Receiving 120 Volts Found Breaker To Be Flipped Due To Bad Fan Control Center Called Homeserve For Approval To Replace Fan Control Center. We Are Also Replacing The Thermostat At The Same Time Through The Customer. Strong Recommendation To Have A Tune Up Performed On This Boiler. Regular Maintenance Will Help Prolong The Life Of Your Boiler, Which Is 32 Years Old. Office Will Be In Touch For Follow Up Appointment Once Part Is In.
Wanda, . Secane, PA
10-17-2023
System Giving E2 Fault. Toggled Power, Error Code Still Persists. Boiler Pressure Found To Be At 0 Psi On Internal Gauge Verified Pressure Is At 0 With External Gauge. Tech Support Stated Boiler Pressure Should Be At 17 And Advised Replacing The Auto Feeder. All Valves Are Open Going Into The Boiler. Auto Feeder Is Failed, Advise Replacement.
Lisa , M. Secane, PA
12-18-2023
Viessmann V7459305-CombiPLUS
System Giving E2 Fault. Toggled Power, Error Code Still Persists. Boiler Pressure Found To Be At 0 Psi On Internal Gauge Verified Pressure Is At 0 With External Gauge. Tech Support Stated Boiler Pressure Should Be At 17 And Advised Replacing The Auto Feeder. All Valves Are Open Going Into The Boiler. Auto Feeder Is Failed, Advise Replacement. Backed Boiler From Water Heater To Increase Boiler Pressure. Boiler Operates At This Time, Suggesting Low Boiler Pressure Was The Cause Of Failed Heating. To Back Fill From The Water Heater I Used A 48 Inch Washing Machine Hose Placing It On The Water Heater Drain And The Boiler Drain. I Opened The Water Heater Drain, Then Unscrewed The Hose Slightly At The Boiler To Purge Air, Retightened Hose When I Got Water Out. Opened The Valve At The Boiler Slowly And Watched As The Pressure Gauge Rose To 20 Psi. I Then Closed The Valve At The Boiler And At The Water Heater And Removed The Hose. Client Opted To Replace The Auto Feeder. Work To Be Completed On Friday. Deposit Paid Via Card. Thank You For Your Time And Business -Bobby
Lisa , M. Secane, PA
12-14-2023
No Heat On 6-7 Year Viessman Gas Boiler. Circulator Pump Seized (looks To Be Due To Corrosion) Replaced Pump And Purged. Water In Boiler Very Red Performed Combustion Test In High Fire System Exhaust Temp Higher Than Desired Indicates Block Needs To Be Cleaned. CO Levels Normal Advise Rust Inhibitor In Boiler And Flushing Out. Boiler Running On Departure
Lisa , M. Secane, PA
09-05-2023
Called Tech Support, They Had Me Check External LWCO, Wires Were Tight. Tech Support Said It Was A Board And They Are Shipping The Board.
Chris , D. Secane, PA
12-18-2023
No Heat
Chris , D. Secane, PA
09-01-2023

©Red Barn Media Group 2024