Our Service Area> springfield,pa

Providing Exceptional Service in Your Community

Air Conditioning Service, Repair and Installation

McGinley Services is one of the leading providers of air conditioning repair and air conditioning service in Springfield, PA, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.

You'll find we take our job seriously and highly value the trust that is placed in us. McGinley Services goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Springfield, PA. Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.

Get Your Quote Today

Called For No Ac On 2005 Heil Ac Found When Turned On Nothing Happened , No Indoor Or Outdoor Unit. Fuse Was Blown Replaced And System Came Right On. Visual Of Indoor And Outdoor Wiring Show No Obvious Signs Of Shorting Or Failure. Suspect It Could Be The Contactor (relay Outside) But Not Sure. Air Filter Is Clean And The Sight Glass Has No Bubbles. May Benefit From Maintenance On Unit. Also Keep Vines From Growing On The Outdoor Unit To Help Keep Up The Efficiency.
Lisa, L. Springfield , PA
02-09-2024
Called For No Ac. On Arrival Unit Set To 82 (so It Doesn’t Run) Turned On Thermostat Noticed Refrigerant Lines Were Very Warm So Moved To Outside. Fan Motor Rated To Run At .80 Max And Is Running At .76 Compressor Amps Rated Max 12.8 And Is Running At 7.94 Capacitor Rated To Be 40/5 And Tested At 41/5.1 Running Load Test Indoor Temp 82f. Outdoor Temp 86f. Refrigerant Pressure 147(52f)/370(111f)with 5 Sub Cooling And 10 Super Heat Refrigerant Pressures And Temperature Are Within Range Of Charging Chart Design Sub Cooling Is 8f At 95 Outdoor Temp Is Low At Current Moment But House Is Very Hot. Electrical Components Outside While Worn Are Working Within Normal Range. Indoor Drain Flushed And Condensate Pump Cycles Normally Indoor Filter Is In Fair Condition Replacing Soon Is Advised Return Static Pressure -0.36 In Return Drop -0.51 After Air Filter Supply Air Static After Coil 0.05 And 0.36 Before The Coil Total Static Pressure 0.87 Changed Air Filter And Made .04 Air Flow Improvement Supply Air Temperature 59f And Return Air Temperature 77f Poor Indoor Air Flow
Mary, M. Springfield, PA
02-09-2024
REPLACED CONDENCER FAN MOTOR WITH UNIVERSAL. AND DUAL CAPACITOR AS WELL AS CONTACTOR. NEW AIR FILTER. SYSTEM IS DRAINING AT THIS TIME. DETAILS OF ALL ITEMS CHECKED AT TESTED AT THIS TIME ARE ON CHECK LIST. AC TUNE UP VISIT NOW AS MEMBERS CAN BE DONE AND PERFORM FULL SYSTEM EVALUATION. BEING THE SYSTEM IS OLDER REPLACEMENT IS SOMETHING RECOMMENDED TO BE DOME SOONER THAN LATER AND WILL CREDIT FULL SERVICE VISIT IF IT IS REPLACED WITH IN 90 DAYS FROM TODAY. AC IS OPERATING ON DEPARTURE
Kelsey , B. Springfield , PA
02-09-2024

©Red Barn Media Group 2024